Sign In | Join Free | My lightneasy.org
China Shenzhen Wisdomlong Technology CO.,LTD logo
Shenzhen Wisdomlong Technology CO.,LTD
Shenzhen Wisdomlong Technology CO.,LTD Work hard and best service for you!
Verified Supplier

7 Years

Home > Redundant Power Supply Module >

Schneider 4 Analog Output Redundant Power Supply Module 30 V 20 MA Voltage Drop 140ACO02000

Shenzhen Wisdomlong Technology CO.,LTD
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment

Schneider 4 Analog Output Redundant Power Supply Module 30 V 20 MA Voltage Drop 140ACO02000

Brand Name : Schneider

Model Number : 140ACO02000

Place of Origin : FR

MOQ : 1

Price : negotiable

Payment Terms : T/T, Western Union

Supply Ability : 100

Delivery Time : 2-3 work days

Packaging Details : New in original box

Brand : Schneider

Model : 140ACO02000

Palce of Origin : FR

Type : Processor/Controller

voltage drop : 30 V 20 mA

module format : Standard

analogue output number : 4

Weight : 0.37 kg

Contact Now

Redundant Power Supply Module Schneider Electric 140ACO02000 Analog output TSC Quantum

Main
range of product
Modicon Quantum automation platform
product or component type
Analogue output module
Complementary
analogue output number
4
addressing requirement
4 output words
loop voltage
12...30 V DC
voltage drop
30 V 20 mA
analogue output range
4...20 mA 0...4096 counts, 12 bits bipolar current
absolute accuracy error
+/- 0.20 % of full scale at 77 °F (25 °C)
linearity
+/- 1 LSB
accuracy drift according to temperature
+/- 0.004 % of full scale/°C
+/- 0.007 % of full scale/°C maximum
isolation between channels
500 V 47...63 Hz AC
750 V for 1 minute DC
update time
3 ms
setting time
900 µs to +/- 0.1 % of the final value
fault type
Open circuit 4...20 mA
bus current requirement
480 mA
power dissipation in W
<= 5.3 W
external power requirement
12...30 V
marking
CE
local signalling
4 LEDs green channel is turned on
4 LEDs red channel fault
1 LED green bus communication is present (Active)
1 LED red external fault
module format
Standard
product weight
0.66 lb(US) (0.3 kg)
Environment
product certifications
CUL
FM Class 1 Division 2
standards
CSA C22.2 No 142
UL 508
resistance to electromagnetic fields
9.14 V/yd (10 V/m) 80...2000 MHz conforming to IEC 801-3
ambient air temperature for operation
32...140 °F (0...60 °C)
ambient air temperature for storage
-40...185 °F (-40...85 °C)
relative humidity
95 % without condensation
operating altitude
<= 16404.2 ft (5000 m)
Ordering and shipping details
Category
18155 - QUANTUM I/O & POWER SUPPLIES
Discount Schedule
PC21
GTIN
00785901792192
Nbr. of units in pkg.
1
Package weight(Lbs)
1.02
Returnability
Y
Country of origin
FR
Offer Sustainability
Sustainable offer status
Green Premium product
RoHS (date code: YYWW)
Compliant - since 0750 - Schneider Electric declaration of conformity Schneider Electric declaration of conformity
REACh
Product environmental profile
Available
Product end of life instructions
Available
Contractual warranty
Warranty period
18 months

OTHER SUPERIOR PRODUCTS

Yasakawa Motor, Driver SG- Mitsubishi Motor HC-,HA-
Westinghouse Modules 1C-,5X- Emerson VE-,KJ-
Honeywell TC-,TK- GE Modules IC -
Fanuc motor A0- Yokogawa transmitter EJA-
Contact person: Anna
E-mail: wisdomlongkeji@163.com
Cellphone: +0086-13534205279

Estimated Shipping Size
Dimensions: 10" x 3" x 5" (25 cm x 8 cm x 13 cm)
Weight: 0 lbs 13 oz (0.37 kg)

Product Related Warnings

Schneider Electric assumes no responsibility for any errors that may appear in this document. If you have any suggestions for improvements or amendments or have found errors in this publication, please notify us.

No part of this document may be reproduced in any form or by any means, electronic or mechanical, including photocopying, without express written permission of Schneider Electric.

All pertinent state, regional, and local safety regulations must be observed when installing and using this product. For reasons of safety and to ensure compliance with documented system data, only the manufacturer should perform repairs to components. When controllers are used for applications with technical safety requirements, please follow the relevant instructions.

Failure to use Schneider Electric software or approved software with our hardware products may result in injury, harm, or improper operating results. Failure to observe this product related warning can result in injury or equipment damage.

Inserting a module (local)

1 Call the Bus Editor
2 Mark a free slot in the local station (left mouse button)
3 Move the mouse pointer over the marked slot
4 Click on the right mouse button
Result: A shortcut menu is opened

Schneider 4 Analog Output Redundant Power Supply Module 30 V 20 MA Voltage Drop 140ACO02000

5 Select New Device
Result: A dialog window opens that displays all available modules
6 Select the desired module from the respective category in the Hardware catalog.
Result: The new module is inserted in the empty slot on the local station.

Schneider 4 Analog Output Redundant Power Supply Module 30 V 20 MA Voltage Drop 140ACO02000

Introduction

The Modicon Quantum with Unity modules follow a system of flat address mapping. To work properly. each module requires a determinate number of bits and/or words. The IEC addressing system is equivalent to the 984LL register addressing. Use the following assignments:

z 0x is now %Mx z

1x is now %Ix z

3x is now %IWx z

4x is now %MWx Use the following table to convert 984LL notation to IEC notation.

Examples

The following examples show the relationship between 984LL register addressing and IEC addressing: 000001 is now %M1 100101 is now %I101 301024 is now %IW1024 400010 is now %MW10

IODDT Addressing

An IODDT allows all information (bits and registers) related to a channel to be handled through a user-defined variable. This variable is defined in the Unity Pro data editor by selecting the appropriate IODDT for the module as a data type and specifying the topological address of the module using the following syntax: %CH[b.e]r.m.c where: z b = bus z e = equipment (drop) z r = rack z m = module slot z c = channel Here is an example of an IODDT for an thermocouple input module in slot 4 of a local rack:

Schneider 4 Analog Output Redundant Power Supply Module 30 V 20 MA Voltage Drop 140ACO02000

Variables in the User Program

You can access all information related to channel 1 of the module using the following variables: z My_Temp_Point1.VALUE for the measured value z My_Temp_Point1.ERROR indicating an out-of-range condition z My_Temp_Point1.WARNING indicating an over-range condition

Word Addressing versus Bit Addressing

Mainly discrete I/O modules can be configured to deliver their I/O data either in word format or in bit format. This can be selected during configuration by selecting either %IW (%MW) or %I (%M). If you need to access a single bit from an I/O module configured to use an I/O word, you can use the syntax %word.bit. The following table gives you the connection between I/O point number and the belonging I/O address in bit and word addressing. The table shows an 32-point input module in the main rack, slot 4 configured with starting address %I1 or %IW1:

I/O channel Bit address (flat addressing) Bit address (topological addressing) Bit address extracted from word (flat addressing) Bit address extracted from word (topological addressing) 1 %I1 %I1.4.1[.0] %IW1.15 %IW1.4.1.1.15 2 %I2 %I1.4.2[.0] %IW1.14 %IW1.4.1.1.14 3 %I3 %I1.4.3[.0] %IW1.13 %IW1.4.1.1.13 • • • 15 %I15 %I1.4.15[.0] %IW1.1 %IW1.4.1.1.1 16 %I16 %I1.4.16[.0] %IW1.0 %IW1.4.1.1.0 17 %I17 %I1.4.17[.0] %IW2.15 %IW1.4.1.2.15 18 %I18 %I1.4.18[.0] %IW2.14 %IW1.4.1.2.14 • • • 31 %I31 %I1.4.31[.0] %IW2.1 %IW1.4.1.2.1 32 %I32 %I1.4.32[.0] %IW2.0 %IW1.4.1.2.0

The 16-point output modules are as follows: z

140DAO84000 (AC Output 24 ... 230 Vac 16x1) z

140DAO84010 (AC Output 24 ... 115 Vac 16x1) z

140DAO84210 (AC Output 100 ... 230 Vac 4x4) z

140DAO84220 (AC Output 48 Vac 4x4) z

140DDO84300 (DC Output 10 ... 60 VDC 2x8 Source) z

140DRA84000 (Relay Output 16x1 Normally Open)

The following list shows the 32-point output modules: z

140DAO85300 (AC Output 230 Vac 4x8 Sink) z

140DDO15310 (DC Output 5 V 4x8 Sink) z

140DDO35300 (DC Output 24 Vdc 4x8 Source) z

140DDO35301 (DC Output 24 Vdc 4x8 Source) z

140DDO35310 (DC Output 24 Vdc True Low 4x8 Sink)

CAUTION

/O Mapping When I/O mapping module inputs using discrete %I references in remote drops, users should not split discrete words between drops. The lowest discrete reference for a drop should start on a word boundary. Failure to follow this instruction can result in injury or equipment damage.


Product Tags:

analog interface module

      

plc power supply module

      
Buy cheap Schneider 4 Analog Output Redundant Power Supply Module 30 V 20 MA Voltage Drop 140ACO02000 product

Schneider 4 Analog Output Redundant Power Supply Module 30 V 20 MA Voltage Drop 140ACO02000 Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Shenzhen Wisdomlong Technology CO.,LTD
*Subject:
*Message:
Characters Remaining: (0/3000)